This is one of a handful of small TLA+ specs I wrote while picking real-world industrial control systems and asking “what’s the minimum state machine that makes this thing not kill someone?” It sits next to my laptop power-state spec and my Dexcom G7 spec — same flavor, different system. A walk-in oven is the one I find most fun to think about because the failure mode is so concrete: a person physically walks inside a room-sized oven, and then the oven heats up.
If you’ve never seen TLA+ before, the interactive microwave page is a gentler introduction. The short version: you describe a system as a set of variables, a set of actions that change those variables, and an invariant that should hold in every reachable state. Then the TLC model checker explores every possible execution and tells you whether the invariant ever breaks. The win is that “every possible execution” includes the weird ones a human would never think to test — the off-by-one ordering of events that turns out to be the bug.
What the spec actually models
A walk-in oven (the kind used for curing coatings, drying lumber, baking large food batches) is essentially a room with a heating element and a door. The dangerous configuration is straightforward: a human is inside, and the temperature is above ambient. The spec tracks three variables — temp, door, and inside — and six actions: Heat, Cool, OpenDoor, CloseDoor, Enter, Exit.
The interlock that does the real work is on Enter:
Enter ==
/\ door = "open"
/\ inside = FALSE
/\ temp = MinTemp
/\ inside' = TRUE
/\ UNCHANGED <<temp, door>>
A person can only step inside if the door is open AND the oven is at MinTemp. And then the safety invariant the model checker is actually trying to falsify is:
Inv4 == inside => temp = MinTemp
If at any reachable state someone is inside and the temperature is above minimum, TLC reports a counterexample with the exact trace that got there. With this spec as written, it doesn’t — Heat is guarded on inside = FALSE, so the heating element can never even turn on while someone is in the chamber. That’s the whole point: encode the interlock and let the checker confirm no path violates it.
The unsafe sequence it’s catching
The real-world bad story this is modeling is the obvious one: tech walks in to check or clean the chamber, door swings shut, controller resumes its program, and the chamber heats while someone is inside. Walk-in ovens have actual physical interlocks and lockout-tagout procedures to prevent this. What the spec does is express those interlocks at the level of “no reachable state has inside true and temp above minimum” and let TLC prove it. If you weaken any of the guards — say, drop the inside = FALSE precondition on Heat — the checker will immediately produce a trace showing exactly how a person ends up cooked.
Scope, honestly
This is a study spec, not a verified industrial controller. The temperature is a single integer ticking up and down by one, there’s no notion of multiple people, no ventilation, no emergency stop, no temperature sensor failure, no door-stuck-open behavior. The config (TargetTemp = 20, MaxTemp = 100, MinTemp = 0) is dimensionless — the point is to give TLC a finite state space to actually explore, not to model real Celsius. The whole module is under 90 lines and the README is one sentence long. I wrote it as part of the same arc of work that led into my ai4fm research on getting LLMs to generate TLA+, and it doubles as one of the example systems I keep in my back pocket when explaining to someone what TLA+ actually buys you on a system they can picture.
The repo is at EricSpencer00/tla-walk-in-oven — the spec is Oven.tla and the config that feeds it to TLC is Oven.cfg. If you have the TLA+ Toolbox or tla2tools.jar installed, it runs in seconds.